We're one of the most professional FA One-stop suppliers in China.Our main products including servo motor, planetary gearbox, inverter and PLC, HMI.Brands including Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki ,Scheider, Siemens , Omron and etc.; Shipping time: Within 3-5 working days after getting the payment. Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on
Spec Detail
Item | Specifications |
---|---|
Part Number | MDDHT3530E |
Details | A5E series Position control type without the safety function |
Family Name | MINAS A5 |
Series | A5E series |
Type | Position control type |
Frame | D-Frame |
Frequency response | 2.3 kHz |
Control method | Position control |
Safety Function | without |
Power device Max. current rating | 30A |
Current detector current rating | 30A |
Supply voltage | Single/3-phase 200 V |
I/F Classification of type | Analog/Pulse |
Dimensions (W) (Unit: mm) | 85 |
Dimensions (H) (Unit: mm) | 150 |
Dimensions (D) (Unit: mm) | 170 |
Mass (kg) | 1.8 |
Environment | For more details, please refer to the instruction manual. |
Basic Specifications
Item | Specifications |
---|---|
Input power: Main circuit | Single/3-phase 200 to 240V +10% -15% 50/60 Hz |
Input power: Control circuit | Single phase 200 to 240V +10% -15% 50/60 Hz |
Encoder feedback | 20-bit (1048576 resolution) incremental encoder, 5-wire serial |
Parallel I/O connector: Control signal Input |
General purpose 10 inputs The function of general-purpose input is selected by parameters. |
Parallel I/O connector: Control signal Output |
General purpose 6 output The function of general-purpose output is selected by parameters. |
Parallel I/O connector: Analog signal Output |
2 outputs (Analog monitor: 2 output) |
Parallel I/O connector: Pulse signal Input |
2 inputs (Photo-coupler input, Line receiver input) |
Parallel I/O connector: Pulse signal Output |
4 outputs (Line driver: 3 output, open collector: 1 output) |
Communication function | USB |
Communication function: USB | USB interface to connect to computers for parameter setting or status monitoring. |
Regeneration | Built-in regenerative resistor (external resistor is also enabled.) |
Control mode | Switching among the following 3 mode is enabled, (1) Position control, (2) Internal velocity command, (3) Position/Internal velocity command |
Multifunctional capabilities to match various needs
◎Supports all positions, speeds and torque modes (w/ built-in positioning function).
◎High-precision position latch and comparison
◎Communication cycle can be set to any time between 2 ms and 62.5 μs.
Simple network
◎Satisfies both high performance and low cost requirements.
◎Synchronization established by communication IC
◎Easier development of compatible equipment