We're one of the most professional FA One-stop suppliers in China.Our main products including servo motor, planetary gearbox, inverter and PLC, HMI.Brands including Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki ,Scheider, Siemens , Omron and etc.; Shipping time: Within 3-5 working days after getting the payment. Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on
Specifications
Power supply voltage | No D in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC |
|
Operating voltage range | 85% to 110% of rated supply voltage | |
Power consumption | E5GN Screw terminal block E5GN-[]-C Screwless clamp terminal block |
100 to 240 VAC: 5.5 VA (max.) 24 VAC/VDC: 3 VA/2 W (max.) 100 to 240 VAC: 5.5 VA (max.) |
Sensor input | Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C Voltage input: 0 to 50 mV |
|
Models with analog inputs Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V |
||
Input impedance | Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB.) |
|
Control method | ON/OFF control or 2-PID control (with auto-tuning) | |
Control outputs |
Relay output | SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA |
Voltage output (for driving SSR) |
Output voltage: 12 VDC ± 15% (PNP), max. load current: 21 mA, with short-circuit protection circuit |
|
Current output | 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000 |
|
Auxiliary outputs |
Number of outputs | 1 or 2 max. (Depends on the model.) |
Output specifications |
Relay output: SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA |
|
Event inputs |
Number of inputs | 2 |
External contact input specifications |
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. Current flow: Approx. 7 mA per contact |
|
Setting method | Digital setting using front panel keys | |
Indication method | 11-segment digital display and individual indicators (7-segment display also possible) Character height: PV: 7.5 mm, SV: 3.6 mm |
|
Multi SP | Up to four set points (SP0 to SP3) can be saved and selected using event inputs, key operations, or serial communications. |
|
Bank switching | Not supported | |
Other functions | Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (including SSR failure and heater over current detection), 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment |
|
Ambient operating temperature | -10 to 55 °C (with no condensation or icing), for 3-year warranty: -10 to 50 °C |
|
Ambient operating humidity | 25% to 85% | |
Storage temperature | -25 to 65 °C (with no condensation or icing) |
More model
E5GN-RT E5GN-R1T E5GN-R1BT E5GN-R101T-FLK E5GN-R103T-FLK E5GN-R2T E5GN-R2HT E5GN-R2BT E5GN-R203T-FLK
E5GN-QT E5GN-Q1T E5GN-Q1BT E5GN-Q101T-FLK E5GN-Q103T-FLK E5GN-Q2T E5GN-Q2HT E5GN-Q2BT E5GN-Q203T-FLK
E5GN-C1T E5GN-C1BT E5GN-C101T-FLK E5GN-C103T-FLK