We're one of the most professional FA One-stop suppliers in China.Our main products including servo motor, planetary gearbox, inverter and PLC, HMI.Brands including Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki ,Scheider, Siemens , Omron and etc.; Shipping time: Within 3-5 working days after getting the payment. Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on
Description
TeSys F contactor, 3 poles (3NO), 265A/1000V AC-3, for motor applications up to 132kW@400V. It provides a low sealed consumption 24V DC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Specifications
Range | TeSys |
---|---|
Range of product | TeSys F |
product or component type | Contactor |
Device short name | LC1F |
contactor application | Resistive load Motor control |
Utilisation category | AC-3 AC-1 AC-4 |
poles description | 3P |
[Ue] rated operational voltage | <= 1000 V AC-1 <= 690 V AC-3 <= 690 V AC-4 <= 460 V DC |
[Uc] control circuit voltage | 24 V DC |
[Ie] rated operational current | 350 A (at <40 °C) at <= 440 V AC AC-1 265 A (at <55 °C) at <= 440 V AC AC-3 |
[Uimp] rated impulse withstand voltage | 8 kV |
---|---|
[Ith] conventional free air thermal current | 350 A (at 40 °C) |
Rated breaking capacity | 2120 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 2200 A 40 °C - 10 s 1230 A 40 °C - 30 s 950 A 40 °C - 1 min 620 A 40 °C - 3 min 480 A 40 °C - 10 min |
Associated fuse rating | 315 A aM at <= 440 V 400 A gG at <= 440 V |
Average impedance | 0.3 mOhm - Ith 350 A 50 Hz |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
Power dissipation per pole | 37 W AC-1 21 W AC-3 |
Overvoltage category | III |
power pole contact composition | 3 NO |
Motor power kW | 132 kW at 380...400 V AC 50/60 Hz (AC-3) 140 kW at 415 V AC 50/60 Hz (AC-3) 140 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660...690 V AC 50/60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) 75 kW at 220...230 V AC 50/60 Hz (AC-3) 51 kW at 400 V AC 50/60 Hz (AC-4) |
Control circuit voltage limits | Operational: 0.85...1.1 Uc (at 55 °C) Drop-out: 0.15...0.2 Uc (at 55 °C) |
Mechanical durability | 10 Mcycles |
Inrush power in W | 750 W (at 20 °C) |
Hold-in power consumption in W | 5 W at 20 °C |
Maximum operating rate | 2400 cyc/h 55 °C |
Operating time | 40...50 ms closing 40...65 ms opening |
Connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 240 mm² Power circuit: connector 1 cable(s) 240 mm² Power circuit: bolted connection |
Tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
mounting support | Plate |
Heat dissipation | 5 W |
motor power range | 55…100 kW at 200…240 V 3 phases 110…220 kW at 480…500 V 3 phases 110…220 kW at 380…440 V 3 phases |
Motor starter type | Direct on-line contactor |
Contactor coil voltage | 24 V DC standard |
Standards | JIS C8201-4-1 IEC 60947-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1 |
Product certifications | LROS (Lloyds register of shipping) ABS RINA BV CSA UL RMRoS DNV CB UKCA |
Compatibility code | LC1F |
Control circuit type | DC standard |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 |
---|---|
Protective treatment | TH |
Ambient air temperature for operation | -5…55 °C |
Ambient air temperature for storage | -60…80 °C |
Permissible ambient air temperature around the device | -40…70 °C |
Height | 203 mm |
Width | 201.5 mm |
Depth | 213 mm |
Operating altitude | 3000 m without derating |
net weight | 7.44 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 25.0 cm |
Package 1 Width | 25.0 cm |
Package 1 Length | 25.1 cm |
Package 1 Weight | 8.0 kg |