We're one of the most professional FA One-stop suppliers in China.Our main products including servo motor, planetary gearbox, inverter and PLC, HMI.Brands including Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki ,Scheider, Siemens , Omron and etc.; Shipping time: Within 3-5 working days after getting the payment. Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on
MS132-20
The MS132-20 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 20.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
Specifications
Brand | ABB |
Current Rating | 16-20A |
Product Net Width | 45 mm |
Product Net Height | 97.8 mm |
Product Net Depth / Length | 86.55 mm |
Product Net Weight | 0.31KG |
Rated Service Short-Circuit Breaking Capacity(Ics) |
(230 V AC) 100 kA (250 V DC) 3 Poles in Series 10 kA (400 V AC) 100 kA (440 V AC) 30 kA (500 V AC) 20 kA (690 V AC) 3 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) |
(230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 30 kA (500 V AC) 20 kA (690 V AC) 3 kA |
Rated Instantaneous Short-Circuit Current Setting (Ii) |
300 A |
Setting Rang | 16 ... 20 A |
Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 7.5 kW |
Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 7.5 kW |
Rated Operational Voltage | Main Circuit 690 V AC Main Circuit 250 V DC |
Rated Operational Current (Ie) | 20 A |
Rated Operational Current AC-3 (Ie) | 20 A |
Rated Operational Current AC-3e (Ie) | 20 A |
Rated Operational Current DC-5 (Ie) | 20 A |
Rated Frequency (f) | Main Circuit 50 Hz Main Circuit 60 Hz |
Operating Frequency (fsw) | 0 ... 400 Hz |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
Rated Insulation Voltage (Ui) | 690 V |
Power Loss | at Rated Operating Conditions per Pole 1.5 ... 2.3 W |